"Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation." - Information and Links:

Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation. - Info and Reading Options

"Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation." and the language of the book is English.


“Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” Metadata:

  • Title: ➤  Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.
  • Authors: ➤  
  • Language: English

Edition Identifiers:

  • Internet Archive ID: pubmed-PMC3580919

AI-generated Review of “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.”:


"Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation." Description:

The Internet Archive:

This article is from <a href="//archive.org/search.php?query=journaltitle%3A%28Frontiers%20in%20Neuroengineering%29" rel="nofollow">Frontiers in Neuroengineering</a>, <a href="//archive.org/search.php?query=journaltitle%3A%28Frontiers%20in%20Neuroengineering%29%20AND%20volume%3A%286%29" rel="nofollow">volume 6</a>.<h2>Abstract</h2>Electrocortical stimulation remains the standard for functional brain mapping of eloquent areas to prevent postoperative functional deficits. The aim of this study was to investigate whether the short-train technique (monopolar stimulation) and Penfield's technique (bipolar stimulation) would induce different effects on brain oscillatory activity in awake patients, as quantified by electrocorticography (ECoG). The study population was seven patients undergoing brain tumor surgery. Intraoperative bipolar and monopolar electrical stimulation for cortical mapping was performed during awake surgery. ECoG was recorded using 1 × 8 electrode strip. Spectral estimation was calculated using a parametric approach based on an autoregressive model. Wavelet-based time-frequency analysis was then applied to evaluate the temporal evolution of brain oscillatory activity. Both monopolar and bipolar stimulation produced an increment in delta and a decrease in beta powers for the motor and the sensory channels. These phenomena lasted about 4 s. Comparison between monopolar and bipolar stimulation showed no significant difference in brain activity. Given the importance of quantitative signal analysis for evaluating response accuracy, ECoG recording during electrical stimulation is necessary to characterize the dynamic processes underlying changes in cortical responses in vivo. This study is a preliminary approach to the quantitative analysis of post-stimulation ECoG signals.

Read “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.”:

Read “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” by choosing from the options below.

Available Downloads for “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.”:

"Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation." is available for download from The Internet Archive in "texts" format, the size of the file-s is: 8.74 Mbs, and the file-s went public at Sat Oct 25 2014.

Legal and Safety Notes

Copyright Disclaimer and Liability Limitation:

A. Automated Content Display
The creation of this page is fully automated. All data, including text, images, and links, is displayed exactly as received from its original source, without any modification, alteration, or verification. We do not claim ownership of, nor assume any responsibility for, the accuracy or legality of this content.

B. Liability Disclaimer for External Content
The files provided below are solely the responsibility of their respective originators. We disclaim any and all liability, whether direct or indirect, for the content, accuracy, legality, or any other aspect of these files. By using this website, you acknowledge that we have no control over, nor endorse, the content hosted by external sources.

C. Inquiries and Disputes
For any inquiries, concerns, or issues related to the content displayed, including potential copyright claims, please contact the original source or provider of the files directly. We are not responsible for resolving any content-related disputes or claims of intellectual property infringement.

D. No Copyright Ownership
We do not claim ownership of any intellectual property contained in the files or data displayed on this website. All copyrights, trademarks, and other intellectual property rights remain the sole property of their respective owners. If you believe that content displayed on this website infringes upon your intellectual property rights, please contact the original content provider directly.

E. Fair Use Notice
Some content displayed on this website may fall under the "fair use" provisions of copyright law for purposes such as commentary, criticism, news reporting, research, or educational purposes. If you believe any content violates fair use guidelines, please reach out directly to the original source of the content for resolution.

Virus Scanning for Your Peace of Mind:

The files provided below have already been scanned for viruses by their original source. However, if you’d like to double-check before downloading, you can easily scan them yourself using the following steps:

How to scan a direct download link for viruses:

  • 1- Copy the direct link to the file you want to download (don’t open it yet).
  • (a free online tool) and paste the direct link into the provided field to start the scan.
  • 2- Visit VirusTotal (a free online tool) and paste the direct link into the provided field to start the scan.
  • 3- VirusTotal will scan the file using multiple antivirus vendors to detect any potential threats.
  • 4- Once the scan confirms the file is safe, you can proceed to download it with confidence and enjoy your content.

Available Downloads

  • Source: Internet Archive
  • Internet Archive Link: Archive.org page
  • All Files are Available: Yes
  • Number of Files: 14
  • Number of Available Files: 14
  • Added Date: 2014-10-25 00:58:51
  • Scanner: Internet Archive Python library 0.7.5
  • PPI (Pixels Per Inch): 300
  • OCR: ABBYY FineReader 9.0

Available Files:

1- Text PDF

  • File origin: original
  • File Format: Text PDF
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001.pdf
  • Direct Link: Click here

2- JPEG Thumb

  • File origin: original
  • File Format: JPEG Thumb
  • File Size: 0.00 Mbs
  • File Name: __ia_thumb.jpg
  • Direct Link: Click here

3- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3580919_files.xml
  • Direct Link: Click here

4- JSON

  • File origin: original
  • File Format: JSON
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3580919_medline.json
  • Direct Link: Click here

5- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3580919_meta.sqlite
  • Direct Link: Click here

6- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3580919_meta.xml
  • Direct Link: Click here

7- DjVu

  • File origin: derivative
  • File Format: DjVu
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001.djvu
  • Direct Link: Click here

8- Animated GIF

  • File origin: derivative
  • File Format: Animated GIF
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001.gif
  • Direct Link: Click here

9- Abbyy GZ

  • File origin: derivative
  • File Format: Abbyy GZ
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001_abbyy.gz
  • Direct Link: Click here

10- DjVuTXT

  • File origin: derivative
  • File Format: DjVuTXT
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001_djvu.txt
  • Direct Link: Click here

11- Djvu XML

  • File origin: derivative
  • File Format: Djvu XML
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001_djvu.xml
  • Direct Link: Click here

12- Single Page Processed JP2 ZIP

  • File origin: derivative
  • File Format: Single Page Processed JP2 ZIP
  • File Size: 0.01 Mbs
  • File Name: PMC3580919-fneng.2013.00001_jp2.zip
  • Direct Link: Click here

13- Scandata

  • File origin: derivative
  • File Format: Scandata
  • File Size: 0.00 Mbs
  • File Name: PMC3580919-fneng.2013.00001_scandata.xml
  • Direct Link: Click here

14- Archive BitTorrent

  • File origin: metadata
  • File Format: Archive BitTorrent
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3580919_archive.torrent
  • Direct Link: Click here

Search for “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” downloads:

Visit our Downloads Search page to see if downloads are available.

Find “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” in Libraries Near You:

Read or borrow “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” from your local library.

Buy “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” online:

Shop for “Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation.” on popular online marketplaces.



Find "Frequency And Time-frequency Analysis Of Intraoperative ECoG During Awake Brain Stimulation." in Wikipdedia