"Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis." - Information and Links:

Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis. - Info and Reading Options

"Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis." and the language of the book is English.


“Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” Metadata:

  • Title: ➤  Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.
  • Authors: ➤  
  • Language: English

Edition Identifiers:

  • Internet Archive ID: pubmed-PMC3573930

AI-generated Review of “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.”:


"Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis." Description:

The Internet Archive:

This article is from <a href="//archive.org/search.php?query=journaltitle%3A%28Radiation%20Oncology%20(London,%20England)%29" rel="nofollow">Radiation Oncology (London, England)</a>, <a href="//archive.org/search.php?query=journaltitle%3A%28Radiation%20Oncology%20(London,%20England)%29%20AND%20volume%3A%287%29" rel="nofollow">volume 7</a>.<h2>Abstract</h2>Background: Hypothyroidism is a frequent late side effect of radiation therapy of the cervical region. Purpose of this work is to develop multivariate normal tissue complication probability (NTCP) models for radiation-induced hypothyroidism (RHT) and to compare them with already existing NTCP models for RHT. Methods: Fifty-three patients treated with sequential chemo-radiotherapy for Hodgkin’s lymphoma (HL) were retrospectively reviewed for RHT events. Clinical information along with thyroid gland dose distribution parameters were collected and their correlation to RHT was analyzed by Spearman’s rank correlation coefficient (Rs). Multivariate logistic regression method using resampling methods (bootstrapping) was applied to select model order and parameters for NTCP modeling. Model performance was evaluated through the area under the receiver operating characteristic curve (AUC). Models were tested against external published data on RHT and compared with other published NTCP models. Results: If we express the thyroid volume exceeding X Gy as a percentage (Vx(%)), a two-variable NTCP model including V30(%) and gender resulted to be the optimal predictive model for RHT (Rs = 0.615, p < 0.001. AUC = 0.87). Conversely, if absolute thyroid volume exceeding X Gy (Vx(cc)) was analyzed, an NTCP model based on 3 variables including V30(cc), thyroid gland volume and gender was selected as the most predictive model (Rs = 0.630, p < 0.001. AUC = 0.85). The three-variable model performs better when tested on an external cohort characterized by large inter-individuals variation in thyroid volumes (AUC = 0.914, 95% CI 0.760–0.984). A comparable performance was found between our model and that proposed in the literature based on thyroid gland mean dose and volume (p = 0.264). Conclusions: The absolute volume of thyroid gland exceeding 30 Gy in combination with thyroid gland volume and gender provide an NTCP model for RHT with improved prediction capability not only within our patient population but also in an external cohort.

Read “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.”:

Read “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” by choosing from the options below.

Available Downloads for “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.”:

"Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis." is available for download from The Internet Archive in "texts" format, the size of the file-s is: 11.57 Mbs, and the file-s went public at Wed Oct 29 2014.

Legal and Safety Notes

Copyright Disclaimer and Liability Limitation:

A. Automated Content Display
The creation of this page is fully automated. All data, including text, images, and links, is displayed exactly as received from its original source, without any modification, alteration, or verification. We do not claim ownership of, nor assume any responsibility for, the accuracy or legality of this content.

B. Liability Disclaimer for External Content
The files provided below are solely the responsibility of their respective originators. We disclaim any and all liability, whether direct or indirect, for the content, accuracy, legality, or any other aspect of these files. By using this website, you acknowledge that we have no control over, nor endorse, the content hosted by external sources.

C. Inquiries and Disputes
For any inquiries, concerns, or issues related to the content displayed, including potential copyright claims, please contact the original source or provider of the files directly. We are not responsible for resolving any content-related disputes or claims of intellectual property infringement.

D. No Copyright Ownership
We do not claim ownership of any intellectual property contained in the files or data displayed on this website. All copyrights, trademarks, and other intellectual property rights remain the sole property of their respective owners. If you believe that content displayed on this website infringes upon your intellectual property rights, please contact the original content provider directly.

E. Fair Use Notice
Some content displayed on this website may fall under the "fair use" provisions of copyright law for purposes such as commentary, criticism, news reporting, research, or educational purposes. If you believe any content violates fair use guidelines, please reach out directly to the original source of the content for resolution.

Virus Scanning for Your Peace of Mind:

The files provided below have already been scanned for viruses by their original source. However, if you’d like to double-check before downloading, you can easily scan them yourself using the following steps:

How to scan a direct download link for viruses:

  • 1- Copy the direct link to the file you want to download (don’t open it yet).
  • (a free online tool) and paste the direct link into the provided field to start the scan.
  • 2- Visit VirusTotal (a free online tool) and paste the direct link into the provided field to start the scan.
  • 3- VirusTotal will scan the file using multiple antivirus vendors to detect any potential threats.
  • 4- Once the scan confirms the file is safe, you can proceed to download it with confidence and enjoy your content.

Available Downloads

  • Source: Internet Archive
  • Internet Archive Link: Archive.org page
  • All Files are Available: Yes
  • Number of Files: 14
  • Number of Available Files: 14
  • Added Date: 2014-10-29 01:20:11
  • Scanner: Internet Archive Python library 0.7.5
  • PPI (Pixels Per Inch): 600
  • OCR: ABBYY FineReader 9.0

Available Files:

1- Text PDF

  • File origin: original
  • File Format: Text PDF
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224.pdf
  • Direct Link: Click here

2- JPEG Thumb

  • File origin: original
  • File Format: JPEG Thumb
  • File Size: 0.00 Mbs
  • File Name: __ia_thumb.jpg
  • Direct Link: Click here

3- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3573930_files.xml
  • Direct Link: Click here

4- JSON

  • File origin: original
  • File Format: JSON
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3573930_medline.json
  • Direct Link: Click here

5- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3573930_meta.sqlite
  • Direct Link: Click here

6- Metadata

  • File origin: original
  • File Format: Metadata
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3573930_meta.xml
  • Direct Link: Click here

7- DjVu

  • File origin: derivative
  • File Format: DjVu
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224.djvu
  • Direct Link: Click here

8- Animated GIF

  • File origin: derivative
  • File Format: Animated GIF
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224.gif
  • Direct Link: Click here

9- Abbyy GZ

  • File origin: derivative
  • File Format: Abbyy GZ
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224_abbyy.gz
  • Direct Link: Click here

10- DjVuTXT

  • File origin: derivative
  • File Format: DjVuTXT
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224_djvu.txt
  • Direct Link: Click here

11- Djvu XML

  • File origin: derivative
  • File Format: Djvu XML
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224_djvu.xml
  • Direct Link: Click here

12- Single Page Processed JP2 ZIP

  • File origin: derivative
  • File Format: Single Page Processed JP2 ZIP
  • File Size: 0.01 Mbs
  • File Name: PMC3573930-1748-717X-7-224_jp2.zip
  • Direct Link: Click here

13- Scandata

  • File origin: derivative
  • File Format: Scandata
  • File Size: 0.00 Mbs
  • File Name: PMC3573930-1748-717X-7-224_scandata.xml
  • Direct Link: Click here

14- Archive BitTorrent

  • File origin: metadata
  • File Format: Archive BitTorrent
  • File Size: 0.00 Mbs
  • File Name: pubmed-PMC3573930_archive.torrent
  • Direct Link: Click here

Search for “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” downloads:

Visit our Downloads Search page to see if downloads are available.

Find “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” in Libraries Near You:

Read or borrow “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” from your local library.

Buy “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” online:

Shop for “Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis.” on popular online marketplaces.



Find "Development Of Multivariate NTCP Models For Radiation-induced Hypothyroidism: A Comparative Analysis." in Wikipdedia